<?xml version="1.0" encoding="UTF-8"?>
<resource xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4/metadata.xsd"
          xmlns="http://datacite.org/schema/kernel-4"
          xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <identifier identifierType="DOI">10.26165/JUELICH-DATA/MLN4JX</identifier>
    <creators><creator><creatorName>Froning, Dieter</creatorName><nameIdentifier schemeURI="https://orcid.org/" nameIdentifierScheme="ORCID">000000032264407X</nameIdentifier><affiliation>(Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering)</affiliation></creator><creator><creatorName>Shi, Yan</creatorName><nameIdentifier schemeURI="https://orcid.org/" nameIdentifierScheme="ORCID">0000-0001-8294-4002</nameIdentifier><affiliation>(Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering)</affiliation></creator><creator><creatorName>Janßen, Holger</creatorName><nameIdentifier schemeURI="https://orcid.org/" nameIdentifierScheme="ORCID">0000-0002-9964-7503</nameIdentifier><affiliation>(Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering)</affiliation></creator><creator><creatorName>Lehnert, Werner</creatorName><nameIdentifier schemeURI="https://orcid.org/" nameIdentifierScheme="ORCID">0000-0002-7423-872X</nameIdentifier><affiliation>(Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering)</affiliation></creator></creators>
    <titles>
        <title>Load changes of a polymer electrolyte fuel cell under different operating conditions</title>
    </titles>
    <publisher>Jülich DATA</publisher>
    <publicationYear>2024</publicationYear>
    <resourceType resourceTypeGeneral="Dataset"/>
    
    <descriptions>
        <description descriptionType="Abstract">A lab scale polymer electrolyte fuel cell (PEFC) with a power of 9 W and an active area of 17.64 cm² was operated with 90% humidity and a stoichiometry factor of two in galvanostatic mode. Load cycles were applied to the PEFC, and the dynamic voltages were monitored. During the experiments shown in jump-run.zip, seven attributes of operating conditions were varied. The experimental setup is specified in detail by Shi [1]. The data files are according to section 5.1 in [1]. The data files in the path jump-run/ contain terms like 0.x-yy, where 0.x is the upper level of the load ramp, starting at 0.2 A cm-2, yy is a numbering of the set of operating conditions, listed in the file 'ramp-up-Experimental setup of DoE methode.pdf'. The parameters A to G are according to Table 5-1 in [1]. The files in the path ramp-up/ contain experiments operated under stepwise increasing electrical load as specified in the file 'jump-dynamic-Experimental setup of dynamic DoE methode.pdf'. The parameters A to G are according to Table 6-1 in [1]. Data with constant operating conditions and different ramp characteristics are published by Froning and et al. [2].</description>
    </descriptions>
    <contributors><contributor contributorType="ContactPerson"><contributorName>Froning, Dieter</contributorName><affiliation>(Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering)</affiliation></contributor></contributors>
</resource>