View: |
Part 1: Document Description
|
|
Citation |
|
|---|---|
|
Title: |
FZJ 1056 cm² PEM electrolysis stack |
|
Identification Number: |
doi:10.26165/JUELICH-DATA/IUF96L |
|
Distributor: |
Jülich DATA |
|
Date of Distribution: |
2026-01-27 |
|
Version: |
2 |
|
Bibliographic Citation: |
Hoppe, Eugen; Holger Janßen; Sebastian Holtwerth; Martin Müller, 2026, "FZJ 1056 cm² PEM electrolysis stack", https://doi.org/10.26165/JUELICH-DATA/IUF96L, Jülich DATA, V2 |
|
Citation |
|
|
Title: |
FZJ 1056 cm² PEM electrolysis stack |
|
Identification Number: |
doi:10.26165/JUELICH-DATA/IUF96L |
|
Authoring Entity: |
Hoppe, Eugen (Forschungszentrum Jülich GmbH, IET-4 Electrochemical Process Engineering) |
|
Holger Janßen (Forschungszentrum Jülich GmbH, IET-4 Electrochemical Process Engineering) |
|
|
Sebastian Holtwerth (Forschungszentrum Jülich GmbH, IET-4 Electrochemical Process Engineering) |
|
|
Martin Müller (Forschungszentrum Jülich GmbH, IET-4 Electrochemical Process Engineering) |
|
|
Distributor: |
Jülich DATA |
|
Access Authority: |
Hoppe, Eugen |
|
Depositor: |
Hoppe, Eugen |
|
Date of Deposit: |
2025-12-12 |
|
Study Scope |
|
|
Keywords: |
Engineering |
|
Abstract: |
The data set under consideration provides the technical drawings of a PEM electrolysis stack with an active cell area of 1056 cm². The stack was developed at the Institute of Energy Technologies (IET-4) at Forschungszentrum Jülich. The primary function of this stack is to facilitate the precise and meticulous testing of diverse components utilized in the PEM electrolysis process, employing a technical scale for accurate measurement. |
|
Methodology and Processing |
|
|
Sources Statement |
|
|
Data Access |
|
|
Notes: |
CC0 Waiver |
|
The dataset was published prematurely. Public access will be granted as soon as our revision process is complete. |
|
|
Other Study Description Materials |
|
|
Related Publications |
|
|
Citation |
|
|
Identification Number: |
10.1016/j.apenergy.2026.128538 |
|
Bibliographic Citation: |
Eugen Hoppe, Holger Janßen, Sebastian Holtwerth, Michael Hehemann, Walter Zwaygardt, Martin Müller, The significance of a polarization curve - analysis of a 60-cell polymer electrolyte water electrolysis stack, Applied Energy, Volume 426, Part A, 2026, 128538 |
|
Label: |
00_FZJ 1056cm² PEM electrolysis stack.pdf |
|
Notes: |
application/pdf |
|
Label: |
02_end_plate.pdf |
|
Notes: |
application/pdf |
|
Label: |
02_end_plate.stp |
|
Notes: |
application/octet-stream |
|
Label: |
03_manifold_plate.pdf |
|
Notes: |
application/pdf |
|
Label: |
03_manifold_plate.stp |
|
Notes: |
application/octet-stream |
|
Label: |
05_insulation_plate.pdf |
|
Notes: |
application/pdf |
|
Label: |
05_isolation_plate.stp |
|
Notes: |
application/octet-stream |
|
Label: |
06_current_collector_anode.pdf |
|
Notes: |
application/pdf |
|
Label: |
06_current_collector_anode.stp |
|
Notes: |
application/octet-stream |
|
Label: |
07_MPP_anode.pdf |
|
Notes: |
application/pdf |
|
Label: |
07_MPP_anode.stp |
|
Notes: |
application/octet-stream |
|
Label: |
08_MEA.pdf |
|
Notes: |
application/pdf |
|
Label: |
09_gasket.pdf |
|
Notes: |
application/pdf |
|
Label: |
10_PTL.pdf |
|
Notes: |
application/pdf |
|
Label: |
11_bipolar_plate.pdf |
|
Notes: |
application/pdf |
|
Label: |
11_bipolar_plate.stp |
|
Notes: |
application/octet-stream |
|
Label: |
11_expanded_metal.pdf |
|
Notes: |
application/pdf |
|
Label: |
11_expanded_metal.stp |
|
Notes: |
application/octet-stream |
|
Label: |
11_frame.pdf |
|
Notes: |
application/pdf |
|
Label: |
11_frame.stp |
|
Notes: |
application/octet-stream |
|
Label: |
12_MPP_cathode.pdf |
|
Notes: |
application/pdf |
|
Label: |
12_MPP_cathode.stp |
|
Notes: |
application/octet-stream |
|
Label: |
13_current_collector_cathode_short.pdf |
|
Notes: |
application/pdf |
|
Label: |
13_current_collector_cathode_short.stp |
|
Notes: |
application/octet-stream |
|
Label: |
14_stack_assambled.stp |
|
Notes: |