{"@context":"http://schema.org","@type":"Dataset","@id":"https://doi.org/10.26165/JUELICH-DATA/PPAL4B","identifier":"https://doi.org/10.26165/JUELICH-DATA/PPAL4B","name":"Micro-structure of porous transport layers of polymer electrolyte membrane electrolysers","creator":[{"name":"Froning, Dieter","affiliation":"Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering"},{"name":"Müller, Martin","affiliation":"Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering"}],"author":[{"name":"Froning, Dieter","affiliation":"Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering"},{"name":"Müller, Martin","affiliation":"Forschungszentrum Jülich GmbH, IEK-14: Electrochemical Process Engineering"}],"datePublished":"2024-01-23","dateModified":"2024-01-23","version":"1","description":["Porous transport layers for electrolysers, manufactured at the Forschungszentrum Jülich, were visualized by means of Zeiss Xradia Versa CT scans. The grayscale images were segmented into black/white, resolution: 1 µm/px. The samples were either sintered from spherical or formless particles. The nomenclature of the samples is according to: a) Ti45: spherical, HDH: formless particles, b) Thickness of the samples / µm, c) Sinter temperature / °C, d) IEKxx: sample lot, e) Size of the segmented image section, the third dimension is the through-plane direction. A detailed description was published by Borah [1]."],"keywords":["Engineering","Physics","Electrolysers, porous transport layers, micro-structure, images"],"citation":[{"@type":"CreativeWork","text":"D. Borah, Two-phase Flow in Porous Transport Layers of Polymer Electrolyte Membrane Electrolysers, PhD thesis, RWTH Aachen, Germany, 2021. http://hdl.handle.net/2128/28716","@id":"http://hdl.handle.net/2128/28716","identifier":"http://hdl.handle.net/2128/28716"}],"license":{"@type":"Dataset","text":"CC0","url":"https://creativecommons.org/publicdomain/zero/1.0/"},"includedInDataCatalog":{"@type":"DataCatalog","name":"Jülich DATA","url":"https://data.fz-juelich.de"},"publisher":{"@type":"Organization","name":"Jülich DATA"},"provider":{"@type":"Organization","name":"Jülich DATA"},"distribution":[{"@type":"DataDownload","name":"HDH_150_1000_IEK41_900x825x130.raw","fileFormat":"image/x-panasonic-rw","contentSize":96525000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14252"},{"@type":"DataDownload","name":"HDH_400_1000_IEK44_900x750x288.raw","fileFormat":"image/x-panasonic-rw","contentSize":194400000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14258"},{"@type":"DataDownload","name":"HDH_500_1000_IEK21_855x605x385.raw","fileFormat":"image/x-panasonic-rw","contentSize":199150875,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14257"},{"@type":"DataDownload","name":"Ti45_500_800_IEK07_850x680x490.raw","fileFormat":"image/x-panasonic-rw","contentSize":283220000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14253"},{"@type":"DataDownload","name":"Ti45_500_800_IEK08_792x700x455.raw","fileFormat":"image/x-panasonic-rw","contentSize":252252000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14254"},{"@type":"DataDownload","name":"Ti45_500_850_IEK90_850x760x460.raw","fileFormat":"image/x-panasonic-rw","contentSize":297160000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14251"},{"@type":"DataDownload","name":"Ti45_500_850_IEK91_850x700x450.raw","fileFormat":"image/x-panasonic-rw","contentSize":267750000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14255"},{"@type":"DataDownload","name":"Ti45_500_850_IEK92_700x805x480.raw","fileFormat":"image/x-panasonic-rw","contentSize":270480000,"contentUrl":"https://data.fz-juelich.de/api/access/datafile/14256"}]}